The rear of the unit accepts various connections to integrate with your cooling system.
POWER: Connection from
power supply, 12VDC
FAN: Radiator fan con-
nections (2.0A max per
plug, 4.5A total)
TEMP: Temperature sensors
shown on the front display
ATX: Pass-
through lead
for power shut-
down feature
PUMP:
External
pump
INS-FM17/INS-FM16:
Connect an optional flow
meter to display flow rate
ON/SYNC/OFF:
Adjusts LED lighting
of INS-FM16 flow
meter
Power Connection
The temperature sensors and ATX lead
may come pre-connected to your unit.
If not, connect them per the diagram
above.
Connect a 12 Volt 4-pin Molex plug from
the power supply to the power connection
on the rear of the unit.
Fan Connection
This unit has three connections to
power radiator fans. Multiple fans can
be combined into a single plug. (A fan
wiring harness is optionally available from
Koolance).
CAUTION: The total com-
bined amperage of all fans
connected to the unit can not
exceed 4.5A. The maximum
load on a single fan header
is 2.0A.
!
ATX Pass-Through Lead
The ATX pass-through lead is
responsible for sending the shut-
down signal if any sensor reaches the
preset shutdown temperature (See
Display Panel for configuration).
There is no polarity direction with
the ATX lead. Connect the male ATX
power lead from the cooling unit to
your computers main chassis power
button.
Connect the female ATX power lead from
the Slot Adapter to the motherboard’s power
switch connection (often marked “PWRSW”,
“PWSW”, or “PWBT”).
This is the connection that would normally
receive the chassis power button directly.
To Motherboard
Chassis Power
Button
From Cooling
Unit
Flow Meter Connection
The cooling system can show values
for one Koolance INS-FM16, INS-
FM17/N, or INS-FM18 flow meter
(sold separately). The use of a flow
meter is optional.
Connect a flow meter to the
appropriately labeled plug. (Note:
INS-FM18 should connect to the plug
labeled “INS-FM17”.)
CTR-CD12 User Manual v 1.0
1
2
Pump Connection
An external 12 Volt DC pump can be
connected to the unit for speed control.
The maximum available amperage is
2.2A.
CAUTION: This product
can be used with a single
12VDC pump with a maxi-
mum amperage of 2.2A.
!
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1

The rear of the unit accepts various connections to integrate with your cooling system.POWER: Connection from power supply, 12VDCFAN: Radiator fan con

Page 2

CAUTION: Generally, sensors report liquid temperature at the water block, which is typically 5-10°C (9-18°F) lower than the actual heat source. This d

Page 3

6The Koolance flow meter model number (SKU) will flash. Press ▼ or ▲ to adjust this based on the following: • INS-FM16: change to “FM-16” • INS-FM17

Page 4 - ◙ to enable or

7Press ▼ or ▲ to change what this line will display among the options described earlier. Press ◙ to move to line 2, and similarly use ▼ or ▲. Press ◙