Superior Liquid Cooling Systems
®
English v1.02
RP-985, RP-1005
Users Manual
RP-985, RP-1005
Users Manual
www.koolance.com
ISO
9001
Printed in Korea
Vue de la page 0
1 2 3 4 5 6 ... 14 15

Résumé du contenu

Page 1 - User’s Manual

Superior Liquid Cooling Systems®English v1.02RP-985, RP-1005User’s ManualRP-985, RP-1005User’s Manualwww.koolance.comISO 9001Printed in Korea

Page 2 - User Manual

1213User ManualParallel LoopsParallel loops are normally used to help accommodate water blocks with significantly disproportionate flow restriction. T

Page 3 - Table of Contents

1415User ManualWith the connected outlet hose, roughly estimate the length you will need to your first cooler, and cut it.Cut the second hose with eno

Page 4 - Chapter1

1617User ManualFilling & MaintenanceOnce all the water blocks have been connected, the system can be filled with coolant. The fill port is located

Page 5 - Display Panel

1819User ManualFilling & MaintenanceWith normal use, Koolance’s liquid coolant should be replaced every 2-3 years. If it ever becomes contaminated

Page 6

2021User Manualthis procedure may not be possible since there will be no visible air gap.5. My system has boot-up problems, or does not turn on...Make

Page 7 - Chapter2

22Limited WarrantyDisclaimerKoolance Incorporated (“Koolance”) warrants each new Koolance liquid-cooled system (“the system”), against defects in mate

Page 8 - Temperature Sensor Placement

iUser ManualThis User Manual is updated regularly. Please be sure to check our support page for a newer version of this guide: www.koolance.com/suppor

Page 9 - Cooling System

iiiiiUser ManualTable of ContentsSystem Features 1Unit Diagram ...

Page 10 - Hose Lengths

iv1User Manual - Temperature Sensors (x3) - ATX Pass-Thru Wire - Mounting screws - ATX Jumper Wire - User ManualIncluded Hardwareflat-head screw

Page 11 - Chapter3

23User ManualUnit DiagramReservoirReservoir & Pump - The coolant tank is transparent for easy liquid-level monitoring through the front window. It

Page 12 - Testing & Filling

45User Manual System FeaturesAlarm & Shutdown SettingsBy default, the Koolance audio alarm will sound if any sensor reaches 55ºC (131ºF). When

Page 13 - Troubleshooting

67User ManualPositioning the UnitThe cooling unit is designed to operate in one orientation. In other directions, the pump and reservoir may not bleed

Page 14

89User ManualInstallationATX Pass-Through LeadThe ATX pass-through lead is responsible for sending the shut-down signal if any sensor reaches the pres

Page 15 - Disclaimer

1011User ManualInstallationCooler & Tubing ConfigurationThere are a vast number of methods for configuring a liquid cooling system (serial, paral